Rigicon Penile Implants in New Delhi India | Rigi10 H malleable penile prosthesis
Dr Ashish Sabharwal is one of the best Penile Implant surgeon in New Delhi India. He gives full details regarding Rigicon Penile Implants including Benefits and Cost. Dr Ashish is a full member Urological Society of India. He is board certified Urologist and Andrologist. He did his 3 years training at University of Miami, USA. He did his fellowship training in Florida at University of Miami, USA. Dr Ashish Sabharwal has a vast experience and has performed the maximum number of Penile Implants in India (New Delhi) for the best erectile dysfunction treatment in Delhi. For full information on Rigicon Implants Benefits, you can watch my you tube video
What are the advantages of Rigicon Rigi 10H?
Rigicon Implants Benefits:
Hydrophilic Coating: Because of the hydrophilic coating, the implant is easier to place within the penis. Also, as soon as you put the implant in the antibiotic solution, the implant gets coated with antibiotic and this prevents penile implant infection.
Bendable core with memory:
There is no spring back of the implant after bending it. So the implant is easy to conceal.
Lifetime warranty of the implant: The Company promises to provide a new implant, free of cost, if any problem happens with the implant in its lifetime. This warranty is valid even if there is a penile implant infection. Even in Penile Implant infection, they provide lifetime free replacement.
Rigi 10H implant features
Very Easy to Implant
Due to the high bending capacity of rods and hydrophilic coating, it’s very easy to place the implant through a small incision. So, the Operative time is lesser and the bleeding, swelling and pain are less. Thus, there is quicker recovery and less chance of infection.
Many Sizes are available
Rigi 10H is available in six diameters (9 – 10 – 11 – 12 – 13 – 14 mm). So the patients can be offered maximum girth after their penile implant surgery
Excellent Rigidity
Rigi10™ rods thanks to the stainless-steel core reinforced with titanium caps, can easily provide the required column strength for penetration. Axial load of one rod of Rigi10 implant is 6.6 lbs.
Flexible Rod Technology™
Rigi 10 implant has flexible rod technology. This has the following advantages:
- 1. Bends very easily upto an angle of 135 degrees thus stimulates a more natural erection.
- 2. It has good memory. Once bent, the implant stays down with no spring backs. Thus, there is very good concealment.
Rigicon Rigi 10H implant has a long life
Rigi10™ continues to offer satisfactory performance results even after long cycles of simulated tests. Rigicon has tested the Rigi10 9mm implant upto 50,000 bend cycles in the Lab. Based on the 9mm still working perfectly well at 50,000 bend cycles in the lab, I think it’s fair and reasonable to say that the other sizes will exceed 50,000 bending cycles plus, comfortably, given the increasing diameter of the implant. That means life of 10-15 years at least. The Rigicon Company also give a lifetime Global warranty for its implant. If anything happens to the implant, they will give a new implant absolutely free of cost in any part of the world.
Easy to conceal.
Rigi10™ is discreet. No one will know that you have an implant unless you choose to disclose. High bending capacity and minimum spring-back gives you a dependable and easy concealment.
What is the Rigicon Rigi 10 implant cost in India?
Indian Patient | Rs 2,50,000/- |
International Patient | USD 3500/- |
This package cost includes the cost of implant, hospital stay, surgery cost, hospital medicines and any other hospital expenses. The pre-surgery investigations, home medicines and cost of any other treatments which the patient receives during the hospital stay apart from Implant surgery e.g. diabetes treatment are not part of package and they will cost extra.
Which Malleable Penile implant is the best?
Comparison of Rigicon Rigi 10 ; Boston Scientific Tactra; Coloplast Genesis and Shah Implant by surgiwear
Name of Implant |
RIGI 10 |
TACTRA |
GENESIS |
SHAH |
Manufacturer |
Rigicon, Inc |
Boston Scientific |
Coloplast |
Surgiwear |
Manufactured in |
USA |
USA |
USA |
India |
Rod Diameter (mm) |
9 6 10 Sizes 11 12 13 14 |
9.5 3 11 Sizes 13 |
9.5 3 11 Sizes 13 |
9.5 4 11 Sizes 13 15 |
Rod Lengths (Min- Max. length) (cm) |
9-10 14-23
11-12-13 16.5-25 |
9.5 14-22 11 16-24 13 18-26 |
9.5 14-22 11 16-24 13 18-26 |
9.5 9.5 -20 11 11 -24 13 13-24 |
|
|
|
|
|
Rear tip extenters (cms) |
0.5 1 |
0 0.5 1 |
0 0.5 1 |
1.5 2.5 3.5 |
Maximum Total Length |
26 cms |
27cms |
27cms |
27.5cms |
|
|
|
|
|
Hydrophilic Coating |
yes |
No |
Yes |
No |
Core Material |
Stainless steel with Titanium Caps |
Nitinol |
Silver wire |
Only Silicon |
Spring-backs |
No |
No |
No |
Yes |
Warranty |
Lifetime (including device malfunction due to adverse body reactions like infection) |
5 years |
Lifetime (excluding device malfunction due to adverse body reactions) |
Lifetime (including device malfunction due to adverse body reactions like infection |
Implant Cost |
1,60,000 |
1,50,000 |
1,50,000 |
25,000 |
Frequently Asked Questions
YES. Rigicon Rigi 10 implant is MRI compatible.
No, Rigi 10 implant not detected on Metal detectors and airport scanners.
YES. The Company promises to provide a new implant, free of cost, if any problem happens with the implant in its lifetime. This warranty is valid even if there is a penile implant infection. Even in Penile Implant infection, they provide lifetime free replacement.